1.
Radiol. bras ; 49(4): 234-240, July-Aug. 2016. tab, graf
Article in English | LILACS | ID: lil-794796

ABSTRACT

Abstract Objective: To measure the scattered radiation dose at different positions simulating hip surgery. Materials and Methods: We simulated fluoroscopy-assisted hip surgery in order to study the distribution of scattered radiation in the operating room. To simulate the patient, we used a anthropomorphic whole-body phantom, and we used an X-ray-specific detector to quantify the radiation. Radiographs were obtained with a mobile C-arm X-ray system in continuous scan mode, with the tube at 0º (configuration 1) or 90º (configuration 2). The operating parameters employed (voltage, current, and exposure time) were determined by a statistical analysis based on the observation of orthopedic surgical procedures involving the hip. Results: For all measurements, higher exposures were observed in configuration 2. In the measurements obtained as a function of height, the maximum dose rates observed were 1.167 (± 0.023) µSv/s and 2.278 (± 0.023) µSv/s in configurations 1 and 2, respectively, corresponding to the chest level of health care professionals within the operating room. Proximal to the patient, the maximum values were recorded in the position occupied by the surgeon. Conclusion: We can conclude that, in the scenario under study, health care professionals workers are exposed to low levels of radiation, and that those levels can be reduced through the use of personal protective equipment.


Resumo Objetivo: Medir a intensidade da dose de radiação espalhada em diferentes posições simulando uma intervenção cirúrgica no quadril. Materiais e Métodos: Simulou-se uma intervenção cirúrgica no quadril com apoio da fluoroscopia para estudar a distribuição da radiação espalhada no bloco operatório. Para simular o paciente foi utilizado um simulador antropomórfico de corpo inteiro e para medir a radiação utilizou-se um detector específico para medir raios X. Realizaram-se incidências com um equipamento de raios X tipo arco em C móvel, em modo de escopia contínua, com a ampola a 0º (configuração 1) e a 90º (configuração 2). Os parâmetros operacionais utilizados (voltagem, corrente, tempo de exposição) foram determinados por meio de um estudo estatístico resultante da observação de cirurgias ortopédicas de quadril. Resultados: Em todas as medições observaram-se exposições mais elevadas na configuração 2. Nas medições em função da altura, observaram-se os valores máximos da taxa de dose de 1,167 (± 0,023) µSv/s e 2,278 (± 0,023) µSv/s nas configurações 1 e 2, respectivamente, correspondendo à altura do tórax dos profissionais. No estudo em torno do paciente os valores máximos registraramse na posição ocupada pelo médico cirurgião. Conclusão: Concluiu-se que a exposição à radiação dos profissionais é baixa, podendo ainda ser reduzida mediante o uso de equipamentos de proteção individual.

2.
Radiol. bras ; 46(4): 214-220, Jul-Aug/2013. tab, graf
Article in English | LILACS | ID: lil-684585

ABSTRACT

Objective To compare the capacity of mammography, sonoelastography, B-mode ultrasonography and histological analysis to differentiate benign from malignant breast lesions. Materials and Methods A total of 12 histopathologically confirmed breast lesions were documented. The lesions were assessed by means of mammography, B-mode ultrasonography and sonoelastography, and histopathological analysis was utilized as a gold standard. Sensitivity and specificity were calculated. A receiver operating characteristic (ROC) curve was constructed to evaluate the diagnostic performance of the mentioned techniques. Results Sensitivity and specificity in the differentiation between benign and malignant lesions were respectively 100% and 50% for mammography, 100% and 71% for B-mode ultrasonography, and 67% and 83% for sonoelastography. The area under the ROC curve was calculated for the three imaging modalities and corresponded to 0.792 for mammography, 0.847 for B-mode ultrasonography, and 0.806 for sonoelastography. Conclusion Sonoelastography demonstrated higher specificity and lower sensitivity as compared with mammography and B-mode ultrasonography. On the other hand, B-mode ultrasonography had the largest area under the ROC curve. Sonoelastography has demonstrated to be a promising technique to detect and evaluate breast lesions, and could potentially reduce the number of unnecessary biopsies. .


Objetivo Comparar a capacidade de diferenciação de lesões benignas versus malignas por parte da mamografia, ultrassonografia modo-B e elastografia. Materiais e Métodos Um total de 12 lesões mamárias confirmadas histologicamente foi documentado. A avaliação das lesões foi realizada por meio da mamografia, ultrassonografia modo-B e elastografia. Os resultados histopatológicos foram utilizados como técnica padrão ouro. As sensibilidades e as especificidades foram calculadas. A curva receiver operating characteristic (ROC) foi realizada para avaliar o desempenho diagnóstico das técnicas utilizadas. Resultados A sensibilidade e a especificidade na diferenciação entre lesões mamárias benignas e malignas foram 100% e 50%, respectivamente, para a mamografia, e 100% e 71% para a ultrassonografia modo-B. A elastografia obteve sensibilidade de 67% e especificidade de 83%. A área abaixo da curva ROC foi calculada para as três técnicas imaginológicas, sendo 0,792 para a mamografia, 0,847 para a ultrassonografia modo-B e 0,806 para a elastografia. Conclusão A elastografia mostrou ter maior especificidade e menor sensibilidade comparativamente à mamografia e à ultrassonografia modo-B. A ultrassonografia modo-B foi a técnica que demonstrou maior área abaixo da curva ROC. A elastografia mostra-se uma técnica promissora na detecção de doença mamária e, potencialmente, poderá reduzir biópsias desnecessárias. .